

Resmed AirMini™ AutoSet™ Travel CPAP Machine Essentials
What Makes the Best Portable CPAP Machines for Travel?
A high-quality portable CPAP machine should make it simple to get effective CPAP therapy anywhere life leads you. The Resmed AirMini, one of the world’s smallest CPAP machines on the market, offers versatility with multiple algorithms and therapy modes such as auto-adjusting (APAP or automatic positive airway pressure) capabilities as well as a fixed-pressure (continuous positive airway pressure or CPAP) therapy mode, a waterless humidification system, convenient device control with the AirMini app, and more.
Traveling with your CPAP has never been so easy.
Notes:
- The AirMini device is also available in the AutoSet for Her models.
AirMini Travel CPAP: Compatible CPAP Masks
The compatible Resmed AirMini Masks available are listed below. Make sure you pair it with the appropriate mask connector or adapter to ensure compatibility with your AirMini device.
Note: Communicating with your healthcare provider before selecting your mask is vital to ensuring you are getting the safest, most effective CPAP therapy for your unique, personal medical needs.
Compatible Resmed AirMini Masks:
-
Resmed AirFit F20 Full Face Mask
-
Resmed AirTouch F20 Full Face Mask
-
Resmed AirFit F20 for Her Full Face Mask
-
Resmed AirTouch F20 For Her Full Face Mask
-
Resmed AirFit F20 For Her Full Face Mask
-
Resmed AirFit P10 Nasal Pillow Mask
-
Resmed AirFit P10 for Her Nasal Pillow Mask
-
Resmed AirFit N20 Nasal Mask
-
Resmed AirTouch N20 Nasal Mask
-
Resmed AirFit N20 for Her Nasal Mask
-
Resmed AirFit N30 Nasal Cradle Mask
-
Resmed AirFit F30 Full Face Mask
Full Face CPAP Masks
Nasal CPAP Masks
Nasal Pillow CPAP Masks
-
AirMini Waterless Humidification
The HumidX heat moisture exchange cartridges are the standard for Resmed’s waterless humidification system for their AirMini device. Designed to provide comfort and effective humidification for most climates and sleep environments, the HumidX acts as a humidifier by delivering moisture to the pressurized airflow without the use of, or access to water, by recycling the heat and moisture from your own breath.
Prevent dryness and airway irritation during sleep therapy with the HumidX and HumidX Plus.
Notes:
- The HumidX Plus is intended for use in dry and high altitude climates where humidity is low.
- HumidX and HumidX Plus are only compatible with AirFit N20, AirTouch N20, AirFit N30 and AirFit P10 Resmed Masks.
- The AirFit F20 and AirTouch F20 masks are only compatible with the HumidX F20.
- The AirFit F30 mask is not compatible with any HumidX cartridges.
AirMini Accessories
There’s more to successful sleep apnea therapy than just your machine and mask. From the AirMini Travel Bag to AirMini Mount System, Resmed has a wide variety of CPAP accessories available that are designed to enhance your sleep therapy comfort and effectiveness.
- AirMini Setup Packs - While the AirMini only works with a limited list of CPAP Masks, Resmed has curated several Setup Packs for AirMini compatible masks that contain all the essentials you’ll need to get started, including a HumidX cartridges, AirMini tubing, and more. Some of these include mask packs, while others do not — make sure to read the description including on each product page.
- AirMini Travel Bag - Featuring a handle and removable should strap the AirMini Travel Case is large enough to hold the your AirMini device as well as many of your essential CPAP accessories.
- AirMini Power Supply - The Resmed AirMini utilizes a 20W AC Adapter external power supply designed for use in North America.
- AirMini Travel Case - A slim, hard cover case designed to hold and protect your AirMini CPAP Machine from dust, debris, and impact damage.
- AirMini Mask Adapters & Connectors - The compatible AirMini masks require special mask adapters or connectors to attach your mask to the AirMini tubing, replacing the standard elbow included with your CPAP mask. These connectors twist apart to insert/replace the Resmed HumidX cartridges but may be used without them.
- AirMini Mount System - A lightweight, convenient mounting system that allows you to secure your AirMini Travel CPAP Machine to various points such as your bedframe, nightstand, wall, or even the seat pocket on a plane during air travel, eliminating the need for counter space to set up your CPAP equipment.
- AirMini Tubing - With a length of 6.6 ft, 22mm cuffs, and a 15mm inner diameter, the AirMini tubing is designed specifically for use with the AirMini AutoSet Travel CPAP Machine and requires a special mask connector, as mentioned above, to attach your AirMini compatible CPAP mask.
- AirMini Air Filters - Disposable filters included with the AirMini are designed to prevent fine particles and airborne debris from entering your CPAP machine, prolonging the life of your device while simultaneously promoting healthier breathing and more comfortable, effective sleep apnea therapy.
- DC Converter - Allows you to power your AirMini device from the lighter socket in your car (or any 12V or 24V DC power source) found in most vehicles.
- User Guide - Provides crucial information to help direct you on your AirMini journey. Featuring helpful instructions for setting up and assembling your device components, using the AirMini App, utilizing and changing comfort features (such as Ramp and EPR), as well as important warnings and troubleshooting details.
AirMini App
Resmed offers a convenient app to control, manage and monitor your sleep apnea therapy results from your AirMini device. Available on Google and Apple app stores, the AirMini app enables patients to take charge of their sleep apnea treatment by providing access to comfort features, sleep therapy data, and ongoing advice and support with setup and therapy.
Clinicians can also receive your detailed sleep data. Simply download the AirMini app to your smart device or computer, pair your CPAP device with Bluetooth wireless technology, and enjoy access to adjustable setup options, comfort settings, and all the sleep therapy feedback you need for a successful, effective CPAP therapy experience.
-
Download the AirMini™ App for Android devices here.
-
Download the AirMini™ App for Apple/iOS devices here.
Note: The AirMini CPAP Machine is not compatible with the Resmed myAir App. The Resmed AirSense 10, Resmed AirSense 11, Resmed AirCurve 10, Resmed AirCurve 11 utilize the myAir App but are not compatible with the AirMini App.
-
How to Clean Your AirMini
Regularly cleaning your AirMini machine is vital to making sure you receive optimal sleep apnea therapy. The following sections are meant to assist you with cleaning and checking your AirMini CPAP machine.
Detach all connected components of your AirMini device according to the disassembly instructions in the AirMini user guide and ensure your humidifier is removed.
Inspecting your waterless humidifier (HumidX, HumidX Plus, HumidX F20)
- Inspect daily for signs of damage or blockages caused by dust, dirt, or debris.
- HumidX filter cartridges must be replaced within 30 days after opening the sealed package.
- When your humidifier is not in use, store it in a clean, dry location.
Note: The HumidX waterless humidifier cartridges cannot be washed. If dirt or discoloration is detecting prior to 30 days of opening from the sealed package, discard and replace immediately.
Cleaning your AirMini tubing
- Clean and inspect your air tubing weekly. Your AirMini tubing should be replaced every six months, or sooner if discoloration or damage is detected.
- Wash your AirMini tubing in warm water using a mild, non-abrasive liquid detergent.
- Rinse your air tubing thoroughly and allow to dry in a cool, low-humidity location that is out of direct sunlight.
- Check your AirMini tubing and replace if you detect any holes, tears or cracks, or discoloration.
Note: Do not wash your AirMini tubing in a dishwasher or washing machine.
Cleaning your F20/F30/N20/N30/P10 connector for AirMini
- Clean and check your F20 connector every day. Your F20 connector should be replaced once every six months.
- Wash in warm water using a mild, non-abrasive liquid detergent.
- Clean with a soft bristle brush and make sure you focus extra attention on the vent holes.
- Rinse thoroughly under warm, running water. Shake off any excess water and allow the connector to air dry out of direct sunlight.
- Double check that there is no dirt or debris in the vent holes.
Note: Do not wash in a dishwasher or washing machine.
Cleaning your mask
Refer to the corresponding CPAP mask user guide for instructions on cleaning.
Changing your air filter
Replace reusable air filters at least once every 6 months. Replace disposable air filters at least once every 2 weeks. It cannot be washed.
Replace your air filters sooner if you detect are any holes or blockages caused by dust or debris.
To change your air filter:
- Slide the air filter cover off and remove your old air filter.
- Insert a new air filter and reinstall the air filter cover.
Notes:
- Make sure the air filter cover is installed and secure at all times to prevent water and dust from entering your AirMini CPAP machine.
- The use of Resmed approved hypoallergenic filter will result in a small reduction in the accuracy of the delivered pressure at high leaks.
Cleaning your machineWipe the exterior of your Resmed AirMini CPAP machine with a dry cloth every week.
For mask cleaning instructions, please refer to your CPAP mask user guide.
Note: The Resmed AirMini AutoSet Travel CPAP Machine comes with a limited 5-year manufacturer's warranty.
How Long Do CPAP Machines Last?
CPAP machine lifespans can differ based on various factors such as how well your machine is maintained, how often you use your machine, and the quality of your CPAP device. Generally CPAP machines last an average of 5 years and it is typically recommended to replace your device at that time.
Learn more about the ideal replacement schedule for your CPAP supplies with this helpful blog.






















